Jump to content United States-English
HP.com HomeProducts and ServicesSupport and DriversSolutionsHow to Buy
» Contact HP
 
HP ProCurve Networking ProCurve Networking by HP  >  Products & Solutions
»  My ProCurve Sign In

ProCurve Switch 5300xl Series
specifications


 »

HP ProCurve Networking

ProCurve Switch 5308xl
ProCurve Switch 5308xl (J4819A)
Click to enlarge photo

 

How to buy

commercial help me image
 » Call me now

5300xl series support

»Software
»Manuals
»FAQ
»Configuration examples
»Mini-GBIC FAQs
»Datasheet (pdf: 457 KB)
»5300xl reference library
»5300xl customer stories
 

» Overview

 

» Features

 

Specifications

 

» Accessories

 

» Support services

 
» Model differences
» Included accessories
» Ports
» Power supplies
» Physical characteristics
» Memory and processor
» Mounting
» Performance
» Environment
» Electrical characteristics
» Safety

» Standard specifications across all models
» Emissions
» Immunity
» Management
» Standards and protocols

Model differences

HP part numberProCurve Switch 5308xl
(J4819A)
ProCurve Switch 5372xl
(J4848B)
ProCurve Switch 5348xl
(J4849B)
Included accessories3 ProCurve Switch xl 24-Port 10/100-TX Module (J4820B)

2 ProCurve Switch xl 24-Port 10/100-TX Module (J4820B)

Ports8 open module slots

Supports a maximum of 192 auto-sensing 10/100 ports or 128 auto-sensing 10/100/1000 ports

5 open module slots

72 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)

Media Type: Auto-MDIX

Duplex: half or full

Supports a maximum of 192 auto-sensing 10/100 ports or 128 auto-sensing 10/100/1000 ports

2 open module slots

48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)

Media Type: Auto-MDIX

Duplex: half or full

Supports a maximum of 96 auto-sensing 10/100 ports or 64 auto-sensing 10/100/1000 ports

Power suppliesincludes: 1 x J4839A

1 open power supply slots

includes: 1 x J4839A

1 open power supply slots

includes: 1 x J4839A

1 open power supply slots

Physical characteristics
Dimensions15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height)15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height)15.3(d) x 17.4(w) x 5.25(h) in. (38.86 x 44.2 x 13.34 cm) (3U height)
Weight26.65 lb. (12.0 kg), Fully loaded31.05 lb. (14.08 kg), Fully loaded24.65 lb. (11.2 kg), Fully loaded
Memory and processor
FabricMotorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM; packet buffer size: 36 MBMotorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAMMotorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM
ModuleARM7 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM; packet buffer size: 36 MBARM7 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM; packet buffer size: 36 MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance
Latency< 6 µs (FIFO)< 6 µs (FIFO)< 6 µs (FIFO)
Throughputup to 48 million ppsup to 48 million ppsup to 24 million pps
Switch fabric speed76.8 Gbps76.8 Gbps38.4 Gbps
Routing table size10000 entries10000 entries10000 entries
Environment
Operating temperature32ºF to 104ºF (0ºC to 40ºC)32ºF to 104ºF (0ºC to 40ºC)32ºF to 104ºF (0ºC to 40ºC)
Operating relative humidity15% to 95% @ 104ºF (40ºC), non-condensing15% to 95% @ 104ºF (40ºC), non-condensing15% to 95% @ 104ºF (40ºC), non-condensing
Non-operating/Storage temperature-40ºF to 158ºF (-40ºC to 70ºC)-40ºF to 158ºF (-40ºC to 70ºC)-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/Storage relative humidity15% to 95% @ 149ºF (65ºC), non-condensing15% to 95% @ 149ºF (65ºC), non-condensing15% to 95% @ 149ºF (65ºC), non-condensing
Altitudeup to 15000 ft. (4.6 km)up to 15000 ft. (4.6 km)up to 15000 ft. (4.6 km)
Electrical characteristics
Maximum heat dissipation2152 BTU/hr (2270 kJ/hr)2152 BTU/hr (2270 kJ/hr)2152 BTU/hr (2270 kJ/hr)
Voltage100-127 / 200-240 VAC100-127 / 200-240 VAC100-127 / 200-240 VAC
Current8.2 / 3.8 A8.2 / 3.8 A8.2 / 3.8 A
Power consumption630 W630 W630 W
Frequency50 / 60 Hz50 / 60 Hz50 / 60 Hz
Safety
cUL (CSA 950)
EN 60950/IEC 60950
NOM-019-SCFI-1994
UL 1950 3rd edition
cUL (CSA 950)
EN 60950/IEC 60950
NOM-019-SCFI-1994
UL 1950 3rd edition
cUL (CSA 950)
EN 60950/IEC 60950
NOM-019-SCFI-1994
UL 1950 3rd edition

» Return to top 

 

HP part numberProCurve Switch 5304xl
(J4850A)
Included accessories
Ports4 open module slots

Supports a maximum of 96 auto-sensing 10/100 ports or 64 auto-sensing 10/100/1000 ports

Power suppliesincludes: 1 x J4839A

1 open power supply slots

Physical characteristics
Dimensions15.3(d) x 17.4(w) x 5.25(h) in. (38.86 x 44.2 x 13.34 cm) (3U height)
Weight21.71 lb. (9.85 kg), Fully loaded
Memory and processor
FabricMotorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM; packet buffer size: 36 MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance
Latency< 6 µs (FIFO)
Throughputup to 24 million pps
Switch fabric speed38.4 Gbps
Routing table size10000 entries
Environment
Operating temperature32ºF to 104ºF (0ºC to 40ºC)
Operating relative humidity15% to 95% @ 104ºF (40ºC), non-condensing
Non-operating/Storage temperature-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/Storage relative humidity15% to 95% @ 149ºF (65ºC), non-condensing
Altitudeup to 15000 ft. (4.6 km)
Electrical characteristics
Maximum heat dissipation2152 BTU/hr (2270 kJ/hr)
Voltage100-127 / 200-240 VAC
Current8.2 / 3.8 A
Power consumption630 W
Frequency50 / 60 Hz
Safety
cUL (CSA 950)
EN 60950/IEC 60950
NOM-019-SCFI-1994
UL 1950 3rd edition

» Return to top 

 

Standard specifications across all models

Emissions

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

Immunity

EN: EN 55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated: IEC 61000-4-3; 3 V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge: IEC 61000-4-5; 1 kV/2 kV AC
Conducted: IEC 61000-4-6; 3 V
Power frequency magnetic field: IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics: EN 61000-3-2, IEC 61000-3-2
Flicker: EN 61000-3-3, IEC 61000-3-3

Management

ProCurve Manager Plus; ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)

Standards and protocols

Device Management
HTML and telnet management
 
General Protocols
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 3046 DHCP Relay Agent Information Option
 
IP Multicast
RFC 3376 IGMPv3
RFC 3973 PIM Dense Mode
 
MIBs
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
     
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2863 The Interfaces Group MIB
 
Network Management
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
 
OSPF
RFC 2328 OSPFv2
 
QoS/Cos
RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
 
Security
IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2138 RADIUS Authentication
RFC 2866 RADIUS Accounting
Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

» Return to top 

» Download Adobe Acrobat Reader

Printable version
Privacy statementUsing this site means you accept its terms
© 2008 Hewlett-Packard Development Company, L.P.