Jump to content United States-English
HP.com HomeProducts and ServicesSupport and DriversSolutionsHow to Buy
» Contact HP
 
HP ProCurve Networking HP ProCurve Networking  >  Products & Solutions
»  My ProCurve Sign In

ProCurve Switch 2700 Series
(Legacy Product) specifications


 »

HP ProCurve Networking

ProCurve Switch 2724
ProCurve Switch 2724 (J4897A)
Click to enlarge photo

 

How to buy

commercial help me image
 » Call me now

2700 series support

»Software
»Manuals
»FAQ
»Warranty
»2700 reference library
»Datasheet (pdf: 416 KB)
»Download Adobe Acrobat Reader
 

» Overview

 

» Features

 

Specifications

 

» Support services

 
» Model differences
» Ports
» Physical characteristics
» Performance
» Environment
» Electrical characteristics

» Standard specifications across all models
» Mounting
» Safety
» Emissions
» Immunity
» Standards and protocols

Model differences

HP part number ProCurve Switch 2724
(J4897A)
ProCurve Switch 2708
(J4898A)
Ports 24 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T)

8 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T)

Physical characteristics
Dimensions: 9.3 x 17.4 x 1.7 in.
(23.62 x 44.2 x 4.32 cm)
1U height
9.3 x 17.4 x 1.7 in.
(23.62 x 44.2 x 4.32 cm)
1U height
Weight: 7.6 lb (3.45 kg)
fully loaded
6.8 lb (3.08 kg)
fully loaded
Performance
Latency: < 12 µs (LIFO) < 2.5 µs (LIFO)
Throughput: 35.7 million pps 11.9 million pps
Switching capacity: 48 Gbps 16 Gbps
Routing table size: 32000 entries 8000 entries
Environment
Operating temperature: 32 °F to 131 °F (0 °C to 55 °C) 32 °F to 131 °F (0 °C to 55 °C)
Operating relative humidity: 15 % to 95 % at 104 °F (40 °C), noncondensing 15 % to 95 % at 104 °F (40 °C), noncondensing
Non-operating/storage temperature: -40 °F to 158 °F (-40 °C to 70 °C) -40 °F to 158 °F (-40 °C to 70 °C)
Non-operating/storage relative humidty: 15 % to 90 % at 149 °F (65 °C), noncondensing 15 % to 90 % at 149 °F (65 °C), noncondensing
Shock and vibration: HP759, HP760 (similar to IEC 68) HP759, HP760 (similar to IEC 68)
Electrical characteristics
Maximum BTUs: 341 BTU/hr 341 BTU/hr
Voltage: 100-127 VAC/200-240 VAC 100-127 VAC/200-240 VAC
Current: 1.5 A 1.5 A
Power: 100 W 100 W
Frequency: 50/60 Hz 50/60 Hz

» Return to top 

 

Standard specifications across all models

Mounting

Mounts in a standard 19 in. rack (hardware included)

Safety

cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition

Emissions

FCC Class A; EN55022/CISPR-22 Class A; VCCI Class A

Immunity

Generic: EN55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated: IEC 61000-4-3; 3V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)

Standards and Protocols

IEEE 802.3x Flow Control
     

» Return to top 