HP part number
|
ProCurve Switch 8108fl
(J8727A)
|
ProCurve Switch 8116fl
(J8728A)
|
|
Included accessories
|
1 ProCurve Switch fl Redundant Management Module (J8731A)
1 ProCurve 8108fl Redundant Switch Fabric Module (J8729A)
1 ProCurve Switch fl Redundant Power Supply (J8732A)
|
1 ProCurve Switch fl Redundant Management Module (J8731A)
1 ProCurve 8116fl Redundant Switch Fabric Module (J8730A)
2 ProCurve Switch fl Redundant Power Supply (J8732A)
|
|
Ports
|
8 open module slots
Supports a maximum of 80 auto-sensing 100/1000 ports or 16 10-GbE ports or 80 mini-GBICs, or a combination
|
16 open module slots
Supports a maximum of 160 auto-sensing 100/1000 ports or 32 10-GbE ports or 160 mini-GBICs, or a combination
|
|
Power supplies
|
includes: 1 x J8732A
2 open power supply slots
|
includes: 2 x J8732A
1 open power supply slots
|
|
Physical characteristics
|
|
|
|
Dimensions |
21.5(d) x 17.3(w) x 22.7(h) in. (54.61 x 43.94 x 57.66 cm) (13U height) |
21.5(d) x 17.3(w) x 34.8(h) in. (54.61 x 43.94 x 88.39 cm) (20U height) |
|
Weight |
219.7 lb. (99.66 kg)1 8-slot chassis, 2 switch fabric modules, 2 management modules, 2 fan trays, 3 power supplies, 8 internal modules, Fully loaded |
340 lb. (154.22 kg)1 16-slot chassis, 2 switch fabric modules, 2 management modules, 2 fan trays, 3 power supplies, 16 internal modules, Fully loaded |
|
Memory and processor
|
|
|
|
Fabric |
PowerPC IBM405 @ 266 MHz, 16 MB flash, 16 MB SRAM, 256 MB SDRAM |
PowerPC IBM405 @ 266 MHz, 16 MB flash MB, 16 MB SRAM, 256 MB SDRAM |
|
Interface Module |
PowerPC IBM405 @ 266 MHz, 16 MB flash, 256 MB SDRAM; packet buffer size: 128 MB RL-DRAM per module |
PowerPC IBM405 @ 266 MHz, 16 MB flash, 256 MB SDRAM; packet buffer size: 128 MB RL-DRAM per module |
|
Management Module |
PowerPC MPC7410 @ 400 MHz, 16 MB flash, 512 MB compact flash, 1 GB SDRAM |
PowerPC MPC7410 @ 400 MHz, 16 MB flash, 512 MB compact flash, 1 GB SDRAM |
|
Mounting
|
|
|
|
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only. Requires 2 or more persons or lift-jack assistance.
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only. Requires 2 or more persons or lift-jack assistance.
|
|
Performance
|
|
|
|
Latency |
< 25 µs (FIFO 64-byte packets) |
< 25 µs (FIFO 64-byte packets) |
|
Throughput |
up to 119 million pps |
up to 238 million pps |
|
Routing/Switching capacity |
160 Gbps |
320 Gbps |
|
|
Gbps |
Gbps |
|
Routing table size |
100000 entries |
100000 entries |
|
Environment
|
|
|
|
Operating temperature |
41ºF to 104ºF (5ºC to 40ºC) |
41ºF to 104ºF (5ºC to 40ºC) |
|
Operating relative humidity |
15% to 80% @ 104ºF (40ºC), non-condensing |
15% to 80% @ 104ºF (40ºC), non-condensing |
|
Non-operating/Storage temperature |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
|
Non-operating/Storage relative humidity |
0% to 90% @ 149ºF (65ºC), non-condensing |
0% to 90% @ 149ºF (65ºC), non-condensing |
|
Altitude |
up to 15000 ft. (4.57 km) |
up to 15000 ft. (4.57 km) |
|
Electrical characteristics
|
|
|
|
Maximum heat dissipation |
5119 BTU/hr (5401 kJ/hr) |
10238 BTU/hr (10801 kJ/hr) |
|
Voltage |
100-125 / 200-240 VAC |
100-125 / 200-240 VAC |
|
Current |
15 / 7 A |
30 / 15 A |
|
Power consumption |
1500 W |
3000 W |
|
Frequency |
50 / 60 Hz |
50 / 60 Hz |
|
Safety
|
|
|
|
|
CSA 22.2 No. 60950
EN 60950/IEC 60950
UL 1950 3rd edition
UL 60950-1
CAN/CSA 22.2 No. 60950
CAN/CSA 22.2 No. 60950-1
EN 60825
|
CSA 22.2 No. 60950
EN 60950/IEC 60950
UL 1950 3rd edition
UL 60950-1
CAN/CSA 22.2 No. 60950
CAN/CSA 22.2 No. 60950-1
EN 60825
|
|
Notes
|
|
|
|
|
|
This product includes software developed by Trimble Navigation, Ltd.
|
|
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g. J4858B, J4859C) are required. |
|
|
This product includes software developed by Trimble Navigation, Ltd. |
|
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g. J4858B, J4859C) are required. |
|