Jump to content United States-English
HP.com HomeProducts and ServicesSupport and DriversSolutionsHow to Buy
» Contact HP
 
HP ProCurve Networking HP ProCurve Networking  >  Products & Solutions
»  My ProCurve Sign In

ProCurve Switch 2900 Series
specifications


 »

HP ProCurve Networking

ProCurve Switch 2900-24G

ProCurve Switch 2900-24G (J9049A)

Click to enlarge photo

 

How to buy

commercial help me image
 » Call me now

2900 series support

»Software
»2900 series manuals
»ProCurve 620 EPS/RPS FAQs
»10GbE Transceiver FAQs
»Mini-GBIC FAQs
»Datasheet (pdf: 374 KB)
 

»  Overview

 

»  Features

 

Specifications

 

»  Accessories

 

»  Support services

 
» Model differences
» Ports
» Power supplies
» Physical characteristics
» Memory and processor
» Mounting
» Performance
» Environment
» Electrical characteristics
» Safety
» Notes

» Standard specifications across all models
» Emissions
» Immunity
» Management
» Standards and protocols
» Notes

Model differences

HP part number ProCurve Switch 2900-24G
(J9049A)
ProCurve Switch 2900-48G
(J9050A)
Ports 20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)

Media Type: Auto-MDIX

Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 CX4 10-GbE ports (IEEE 802.3ak Type 10Gbase-CX4)

Duplex: full only

2 open 10-GbE X2 transceiver slots

1 RS-232C DB-9 console port

4 dual-personality ports

each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)

Media Type: Auto-MDIX

Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 CX4 10-GbE ports (IEEE 802.3ak Type 10Gbase-CX4)

Duplex: full only

2 open 10-GbE X2 transceiver slots

1 RS-232C DB-9 console port

4 dual-personality ports

each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

Power supplies
Physical characteristics
Dimensions 15.43(d) x 17.44(w) x 1.73(h) in. (39.2 x 44.3 x 4.4 cm) (1U height) 16.93(d) x 17.44(w) x 1.73(h) in. (43.0 x 44.3 x 4.4 cm) (1U height)
Weight 14.11 lb. (6.3 kg) 15.43 lb. (7 kg)
Memory and processor
Processor Freescale PowerPC 8540 @ 667 MHz, 4 MB flash; packet buffer size: 13.5 MB Freescale PowerPC 8540 @ 667 MHz, 4 MB flash; packet buffer size: 22.5 MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only.

Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only.

Performance
1000 Mb Latency < 3.7 µs (FIFO 64-byte packets) < 3.7 µs (FIFO 64-byte packets)
10 Gbps Latency < 2.1 µs (FIFO 64-byte packets) < 2.1 µs (FIFO 64-byte packets)
Throughput up to 74 million pps (64-byte packets) up to 110 million pps
Routing/Switching capacity 101 Gbps 148 Gbps
Switching capacity 115 Gbps 173 Gbps
Routing table size 2000 entries 2000 entries
MAC address table size 64000 entries 64000 entries
Environment
Operating temperature 32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F (0° to 40°C) when using any X2 optic or transceiver 32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F (0° to 40°C) when using any X2 optic or transceiver
Operating relative humidity 15% to 95% @ 104ºF (40ºC), non-condensing 15% to 95% @ 104ºF (40ºC), non-condensing
Non-operating/Storage temperature -40ºF to 158ºF (-40ºC to 70ºC) -40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/Storage relative humidity 15% to 90% @ 149ºF (65ºC), non-condensing 15% to 90% @ 149ºF (65ºC), non-condensing
Altitude up to 15000 ft. (4.6 km) up to 15000 ft. (4.6 km)
Acoustic Power: 49.3 dB; DIN 45635T.19 per ISO 7779 Power: 52 dB; DIN 45635T.19 per ISO 7779
Electrical characteristics
Description The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz
Maximum heat dissipation 683 BTU/hr (721 kJ/hr) 683 BTU/hr (721 kJ/hr)
Voltage 100-127 / 200-240 VAC 100-127 / 200-240 VAC
Current 4.0 / 2.0 A 4.0 / 2.0 A
Power consumption 200 W 200 W
Frequency 50 / 60 Hz 50 / 60 Hz
Safety
CSA 22.2 No. 60950

UL 60950

IEC 60950

EN 60950

CSA 22.2 No. 60950

UL 60950

IEC 60950

EN 60950

Notes
 
One 0.5 m 10-GbE CX4 cable is included.
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
ProCurve 10-GbE CX4 Media Converter (J8439A) can be used only with the two fixed CX4 ports.
One 0.5 m 10-GbE CX4 cable is included.
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
ProCurve 10-GbE CX4 Media Converter (J8439A) can be used only with the two fixed CX4 ports.

»  Return to top  

 

Standard specifications across all models

Emissions

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

Immunity

EN: EN 55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated: IEC 61000-4-3; 3 V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge: IEC 61000-4-5; 1 kV/2 kV AC
Conducted: IEC 61000-4-6; 3 V
Power frequency magnetic field: IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics: EN 61000-3-2, IEC 61000-3-2
Flicker: EN 61000-3-3, IEC 61000-3-3

Management

ProCurve Manager Plus; ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)

Standards and protocols

Device Management
RFC 1591 DNS (client)
HTML and telnet management
 
General Protocols
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 3046 DHCP Relay Agent Information Option
 
IP Multicast
RFC 3376 IGMPv3
 
IPv6
RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2461 IPv6 Neighbor Discovery
RFC 2462 IPv6 Stateless Address Auto-configuration
RFC 2463 ICMPv6
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
     
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4541 IGMP & MLD Snooping Switch
 
MIBs
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 2021 RMONv2 MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2863 The Interfaces Group MIB
 
Network Management
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
 
QoS/Cos
RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
 
Security
IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2138 RADIUS Authentication
RFC 2866 RADIUS Accounting
Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

Notes

One 0.5 m 10-GbE CX4 cable is included.

When using mini-GBICs with this product, mini-GBICs with revision "B" (product number ends with the letter "B", e.g. J4858B, J4859B) or later are required.

ProCurve 10-GbE CX4 Media Converter (J8439A) can be used only with the two fixed CX4 ports.

»  Return to top  

»  Download Adobe Acrobat Reader

Printable version
Privacy statementUsing this site means you accept its terms
© 2008 Hewlett-Packard Development Company, L.P.