| Technical specifications |
| Performance/Scalability/Flexibility |
- 1 to 4 PA-8900 processors (rp4440)
- 1 or 2 PA-8900 processors (rp4410)
- Clock frequency: 800 MHz or 1.0 GHz
- System bus bandwidth: 6.4 GB/s
|
| Cache |
- Level 1 caches: 0.75 MB instruction and 0.75 MB data per processor
- Level 2 cache: 64 MB off-chip, combined instruction/data shared between two CPUs inside the processor module
|
| Main memory |
- Bus bandwidth: 12.8 GB/s
- RAM Type: PC2100 ECC registered DDR266A/B SDRAM
- Capacity: 128 GB Max
- Memory slots: 16 or 32 DIMM slots (depending on your choice of memory board)
|
| Operating system |
HP-UX 11i v1, HP-UX 11i v2, and HP-UX 11i v3
|
| Internal storage devices |
- Internal HDD bays: 2
- HDD bus interface: Ultra320 SCSI
- HDD capacities/speeds: 36 GB, 73 GB, 146 GB and 300 GB
- Removable media: One open bay for DVD
|
| Maximum internal storage |
|
| I/O Expansion slots |
- PCI-X slots available: 6 (2 x 133 MHz, 4 x 66 MHz)
- I/O bandwidth: 4.2 GB/s
|
| Core I/O interconnect |
- 2 x 10/100/1000Base-TX Ethernet
- 2 x Ultra320 SCSI
- Optional 2-port Ultra320 SCSI RAID
- 10/100BT management LAN
- 1 x RS-232 serial ports for general use
- 2 x RS-232 serial ports for the integrated management processor
- 2 x USB
- VGA
|
| Rack-optimized design |
- Rackmount solution: side-mounted rack slides that install without tools
- Fits into all HP Rack System/E, HP 9000/10000 series racks and many 3rd party racks
For a complete list of racks and rack accessories, refer
to http://www.hp.com/racksolutions/ or
http://h18004.www1.hp.com/products/servers/proliantstorage/bcs-rackandpower/index.html
|
| Physical and environmental specifications |
| Physical dimensions - rack |
| Height |
6.8 in. (173 mm); 4 EIA rack units |
| Width |
19 in. (482 mm) |
| Depth |
27.2 in. (690 mm) |
|
| Physical dimensions (standalone) |
| Height |
20.9 in. (530 mm) |
| Width |
10.2 in. (260 mm) |
| Depth |
27.4 in. (695 mm) |
|
| Net weight |
| Maximum configuration |
100 lb. (45.4 kg) |
|
| Temperature |
| Operating |
+41°F to +95°F (+5°C to +35°C) |
| Non-operating |
40°F to +158°F (-40°C to +70°C) |
|
| Humidity |
| Operating |
15% to 80% RH non-condensing |
|
| Altitude |
| Maximum operating |
10,000 ft (3000 m) |
| Maximum non-operating |
15,000 ft (4500 m) |
|
| Power requirements |
| Maximum input current |
8A at 240 VAC |
| Line frequency |
50-60 Hz |
| Maximum power input |
1,368 W (conservative), 1,065 W (typical) Note: these numbers are per system, not per line input |
|
| Power supply |
| Maximum output |
1200 W per supply |
| Number of supplies |
1 or 2 (1+1 configuration; one supply required) |
| Power inlet type |
IEC320-C14 |
|
| Regulatory |
| Regulatory model number |
RSVLA-0201 |
|